SAS 70 Type II Data Center
Data393 Data Center Home

 

Infrastructure

Our SAS 70 Type II facility has been designed to provide you with stability and reliability for your business. With over $30 million dollars invested, our data center infrastructure can support your cooling, power and protection needs.

Power
Data393 Powerware UPS Units

Your company will be able to take advantage of truly redundant power with our unique power infrastructure. Two separate feeds from the energy company Xcel Energy feed into Data393’s facility from the Surrey Ridge substation. Each power feed is routed through a separate bank of Uninterruptible Power Supply (UPS) units and backed by diesel generators.

Some of the power infrastructure we use to protect your business includes

  • Dual Megawatt+ capable diesel generators with a four day fuel supply. Fuel contracts are in place to ensure that in the event an extended power outage the generators will be able to continue to receive a steady supply of fuel.
  • Nine (9) Powerware UPS modules providing immediate power to your critical systems in the event of commercial power loss.
  • Automatic transfer switches for all power sources to ensure smooth transitions to and from commercial power.
  • Power is monitored by our professional, 24x7 on site NOC and backed by professional electricians on call.
  • Full load tests on our critical power infrastructure are performed every month to ensure proper operation.
Redundant Data Center Power by Starline Buss in Data393's Data Center

Power is fully conditioned by the UPS units to ensure that the power delivered to your colocated or hosted equipment is clean and free of defects. This protects you from "brownouts" and surges that sometimes occur with standard commercial power and can cause damage to sensitive electronic equipment.

Power is fully monitored by multiple power monitoring points down to the individual power circuit level. This allows our Data Center Operations and Network Operations Staff to monitor power flow, buss capacity and health of UPS units before an issue occurs. Individual power circuits are connected to intelligent power distribution systems that report usage back to a robust reporting system. This allows you to get reporting on your power usage and address any power consumption issues before it becomes costly.

All colocation customers have the option of having power provided from both of our power feeds delivering you truly redundant power. All power is fed from above head power busses which allow you to have power provisioned in as little as a few hours compared to several days with traditional power systems.

HVAC
Redundant Cooling In Data393's Data Center Via Stulz Air Handling Units

Many times the ability for a data center to provide adequate cooling and humidity to equipment is overlooked. Data393 has spent significant money to ensure that your business is protected. Our colocation and managed hosting facilities are built with redundant cooling and humidification units.

Our cooling systems are separated into two systems. The first system, which provides cooling to our colocation facilities, includes ten (10) 26-ton Stulz air-handling units (AHUs) which provide N+1 redundancy. Six (6) DataAire Aire Flow and one (1) Leibert AHU power the second cooling system that provides cooling to the second cooling system, which supplies our managed hosting environment.

Humidification is handled by a series of ultrasonic humidification units. Ultrasonic humidification provides an efficient method for evenly distributing humidity throughout the data center.

In addition to the equipment we have put in place, we have a highly engineered airflow structure in place that forces cool air through the front of your equipment and reclaim the heated air as it exits. This is done with strict adherence to “hot” and “cold” isles within the data center.

Fire Detection and Suppression

Ensuring that the data center is protected from fire is vital to the security of your business. Data393’s data center uses a multi-zoned above and below detection system. Our Network Operations Center (NOC) monitors any alarms internally and externally by a third party.

In the event of a fire, the fire suppression system is a dry pipe, pre-action system that will not pressurize until at least two (2) monitors are triggered. Should the fire system be engaged, it will only disperse in a tightly localized area directly affected by the triggered monitors.

Environmental Monitoring

We have invested heavily in state of the art monitoring systems that monitor power, HVAC and other environmental controls.  These monitoring systems are constantly displayed within our NOC and are backed up by thorough, regular physical walkthroughs that are performed by NOC and facilities personnel.  

If trouble is detected, audible and visual alarms occur.   NOC and facilities staff respond immediately to resolve any environmental situations.   We also notify any vendors that have responsibility for systems to ensure that all issues are resolved completely and thoroughly. 

Take a tour of our facility and learn more about how we can be the backbone for your IT infrastructure.  Fill out the contact form above or call us at 800-260-4843.

 


Live Sales Chat
Request a Callback

Get Started Now
First Name:

Last Name:

Email Address:

Company Name:

Business Phone:

Mobile Phone:

Area of Interest:

Comments:

 

Managed Hosting | Colocation | Managed Services | Data Center

Home | Our Company | Contact Us
©2008 Data393. All rights reserved. Terms of Service | Acceptable Use | Privacy Policy
Managed Hosting and Colocation | Denver, Colorado | Sales: 1-800-260-4843


Web Design by Precis E-Business